DISCHARGE COEFFICIENT FOR A TRIANGULAR NOTCH WEIR THEORY AND EXPERIMENTAL ANALYSIS

B. ACHOUR, L. AMARA

Abstract


The study deals with the thin-plate triangular notch weir as a flow measurement device. Unlike previous studies on this subject, a theoretical development is proposed which takes into account the effect of the approach flow velocity. Between two well-chosen sections, the energy equation is applied with certain simplifying assumptions 1) the head loss and the effect of both viscosity and surface tension are neglected, 2) Assuming a hydrostatic distribution of the pressure. 3) The effect of the flow streamlines curvature over the weir is neglected. All the parameters influencing the discharge coefficient are well defined in the theoretical equation, as the experiment predicts so well. The theoretical equation of the discharge coefficient is adjusted to be in conformity with the experimental data. The adjusted relationship is a function exclusively of the relative weir height ratio P/h1 and dimensionless number M1=mh1/B, where m is the side slope of the notch, i.e. m horizontal to 1 vertical, h1 corresponds to the upstream water depth measured above the vertex of the notch, and B is the width of the rectangular channel of approach. The corrected theoretical relationship causes a maximum deviation of 6% on the calculation of the discharge coefficient, knowing that the average relative error is less than 1.88%. It is worth noting that among the 168 calculated values of the relative deviation on the computation of the discharge coefficient, 94% are less than 5% meaning that 6% only are greater than 5%, 87% are less than 4%, while 76.2% are less than 3%.


Keywords


V-notch, weir, discharge coefficient, weir height, approach velocity.

Full Text:

PDF

References


ACHOUR B. (1989). Jump flowmeter in a channel of triangular cross-section without weir, Journal of Hydraulic Research, Vol. 27, Issue 2, pp. 205-214.

ACHOUR B., BOUZIANE M.T., NEBBAR K. (2003). Broad-crested triangular flowmeter in rectangular channel, Larhyss Journal, No 3, pp. 7-43.

BOS M.G. (1976). Discharge measurement structures, Laboratorium voor hydraulica aan Afvoerhydrologie, Landbouwhogeschool, Wageningen, The Netherlands, Report 4, May.

BOS M.G. (1989). Discharge Measurement Structures, Third Edition, International Institute for Land Reclamation and Improvement, Wageningen, Netherlands.

HENDERSON F.M. (1966). Open Channel Flow, MacMillan Publishing Company, New York.

KINDSVATER C.E., Carter R.W. (1959). Discharge characteristics of rectangular thin-plate weirs, American Society of Civil Engineers, Transactions, Vol. 124, p. 772.

KULIN G., COMPTON P.R. (1975). A Guide to Methods and Standards for the Measurement of Water Flow, Special Publication 721, National Bureau of Standards, Washington, USA.

SHEN J. (1981). Discharge Characteristics of Triangular-notch Thin-plate Weirs, Geological Survey Water Supply, Paper 1617-B, Washington, USA.

THOMSON J. (1858). On experiments on the measurement of water by triangular notches in weir boards, The British Association for the Advancement of Science, Annual report, p. 181.

THOMSON J. (1861). On experiments on the measurement of water by triangular notches in weir boards, The British Association for the Advancement of Science, Annual report, p. 151.

VATANKHAH A.R., KHAMISABADI M. (2019). General Stage-Discharge Relationship for Sharp-Crested Power Law Weirs. Analytical and Experimental Study, Irrigation and Drainage, Vol. 68, Issue 4, https://doi.org/10.1002/ird.2367, pp. 808-821.


Refbacks

  • There are currently no refbacks.


Creative Commons License